Specifications

NOTE: Buildings that are heated and/or cooled must meet the requirements of the International Energy Conservation Code in effect for the building’s final destination. If you select an insulation system that does not meet these minimum requirements, we will add insulation to meet the code when the building is quoted.

Partitions

Partitions will be constructed of 3" x 16" interlocking flush-type smooth or embossed surfaced panels in a nominal 24-gauge galvanized steel, factory-painted Arctic White. Partitions will be furnished complete with base channel, wall cap and all required fasteners. Partitions will accept all wall accessories such as walk doors, framed openings, louvers, wall opening kits, and windows. In addition to wall accessories, partitions can be supplied with all interior liners and insulation for a complete field-assembled system.
- Optional:
  • Partitions can be supplied embossed in nominal 20-gauge and unembossed in nominal 18-guage galvanized steel, factory-painted Arctic White.

Formed Wall Liner

Interior liner panels will have a maximum coverage width of 32" and overlap with the adjoining liner panel. The interior surface will have 1/4" high x 1" wide ribs on 8" center. The liner will be continuous length from base to eave, except where interrupted by wall accessories. The exterior panel void will have a 16" wide, 3-1/2" thick unfaced R13 fiberglass insulation.
- Optional:
  • A one inch wide thermal tape can be applied to the inside of the exterior panel ribs to abate thermal bridging between the joints
  • A 1/4" layer of continuous, reflective, polyethylene insulation (R-7.75, U-0.13) may be installed outside of the exterior panel ribs.
  • A29 Acoustical Wall System will be accomplished by the system described above including thermal tape, except the liner panel will have 1/8" diameter perforations spaced on 3/8" staggered centers. The system will have an NRC rating of 0.90 and STC rating of 29.

Lock-In Wall Liner

The interior of the buildings will be finished with a factory-assembled insulated metal liner panel having no exposed fasteners except at the matching base, ceiling and accessory trim. Liner panels will be 16" wide, nominal 26-gauge, embossed, galvanized steel, prepainted Arctic White. Insulation will be non-combustible, nominal 1" thick, 2# minimum density fiberglass laminated to the liner panel.
- Optional:
  • The void between the exterior wall panel and the lock-in liner panel will be insulated with 16" wide, 3-1/2" thick R13 unfaced fiberglass insulation.
  • A 1/4" layer of continuous, reflective, polyethylene insulation (R-7.75, U-0.13) may be installed inside of the exterior panel ribs.

Lock-In Plus Wall Liner

The interior of the building will be finished with a factory-assembled, insulated metal liner panel having no exposed fasteners except at the matching base, ceiling and accessory trim. The liner system will have a concealed insulating board of 1-1/2" thick polyisocyanurate foam impaled on rib clips, and the void between the exterior wall panel and the lock-in liner panel will be insulated with 16" wide, 3-1/2" thick R13 unfaced fiberglass insulation. Liner panels will be 16" wide, nominal 26-gauge, embossed galvanized steel, prepainted Arctic White. Insulation will be non-combustible, nominal 1" thick, 2# minimum density fiberglass laminated to the liner panel.
- Optional:
  • A 1/4" layer of continuous, reflective, polyethylene insulation (R7.75, U-0.13) may be installed inside of the exterior panel ribs.

Roll-In Insulation

The interior of the building will be insulated with 16" wide, 3-1/2" thick R13 unfaced fiberglass insulation with separate white metalized polypropylene scrimkraft (PSK) facing stretched across the interlocking panel ribs and held in place with a PVC 1-1/2" wide batten strip attached with #12 self-drilling fasteners.
- Options:
  • A 1/4" layer of continuous, reflective, polyethylene insulation (R-7.75, U-0.13) may be installed inside of the exterior panel ribs.

Friction Fit Insulation

The wall system shall include 3-1/2" thick R13 unfaced fiberglass insulation. The "U" value of the finished wall system shall not exceed 0.16 BTU's per square foot when calculated in accordance with the "Zone Method" contained in ASHRAE "Handbook of Fundamentals", 1981 edition.
Interior finish and vapor barrier for the wall system shall be supplied by others.

Acoustical Wall System

A48 Acoustical Wall System consists of a nominal 24-guage fluted exterior panel with a minimum 16" wide, 3-1/2" thick R13 unfaced fiberglass insulation in panel void. A 1/2" thick sound buffer board will separate the exterior wall system and a nominal 26-gauge flush metal septum panel. The septum panels will be installed perpendicular to the exterior wall panels with the void filled with a minimum 16" wide, 3" thick R13 4# density fiberous acoustical insulation. A vibration retardant tape will be installed between the septum panel ribs and a perforated formed liner panel. The system will have a NRC of 1.00 and STC of 48. Wall accessories may affect overall performance. This system has NOT been sound tested.

Gypsum Board

The wall system shall include 3 1/2" thick, R13 unfaced fiberglass batt insulation, vapor barrier (optional), furring strips and 1/2" thick gypsum board.

6" Studwall

The interior of the building will be finished with a factory-painted, galvanized steel liner panel having a maximum coverage of 32" and overlap with the adjoining liner panel. The interior surface will have 1/4" high x 1" wide ribs on 8" centers. The liner will be continuous in length from base trim to ceiling trim except where interrupted by wall accessories. The interior liner panels will be attached to 3" thick x 1" wide x 14-guage steel studs spaced 16" on center and located at the midpoint of each exterior wall panel. The void between the studs will be filled with 16" wide, 3-1/2" thick R13 unfaced fiberglass insulation. The exterior panel void will be filled with 16" wide, 3-1/2" thick R13 unfaced fiberglass insulation.
- Optional:
  • A 1/4" layer of continuous, reflective polyethylene insulation (R7.75, U-0.13) may be installed inside of the exterior panel ribs.

Drawings

Drawing Name Rev Description Type
A-FL 1 Formed Wall Liner System Approval
A-FL-18 1 18 Gauge Formed Wall Liner System Approval
A-FL-LOW-E 0 Formed Wall Liner Approval
A-LA29 2 A29 Acoustical Wall Liner System Approval
A-LA30 2 A30 Acoustical Wall Liner System Approval
A-LA48 1 A48 Acoustical Wall Liner System Approval
A-LA49 2 A49 Acoustical Wall Liner System Approval
A-LL 0 Lock-In Wall Liner System Without R13 Wall Insulation Approval
A-LL-FF 1 Lock-In Wall Liner System With Fiberglass Wall Insulation Approval
A-LP 1 Lock-In Plus Wall Liner System With Fiberglass Insulation Approval
A-RIN-2 0 TYPE 2 ROLL-IN WALL LINER Approval
A29-AL 8 A29 Acoustical Wall Liner System installation Erection
A29-S 7 A29 Acoustical Wall Liner System Details Erection
A30-AL-NT 2 A30 Acoustical Wall Liner System Installation Erection
A30-S-NT 1 A30 Non Tested Acoustical Wall Liner System Details Erection
A48-AL-NT 3 A48 Acoustical Wall Liner System Installation Erection
A48-S-NT 4 A48 Non Tested Acoustical Wall Liner System Details Erection
A49-AL 6 A49 Acoustical Wall Liner System Installation Erection
A49-S 6 A49 Acoustical Wall Liner System Details Erection
C-STUDWALL-1 1 'C' Studwall System Installation Erection
C-STUDWALL-2 1 'C' Studwall System Installation Erection
FFW-1 2 Friction Fit Wall Insulation Details Erection
FORMED-1 12 Formed Wall Liner Details Erection
FORMED-2 13 Formed Wall Liner Details Erection
FORMED-3 5 Formed Wall Liner With Partition Details Erection
FORMPLUS-1 5 Formed Plus Wall Liner System Erection
FORMPLUS-2 3 Formed Plus Wall Liner System Erection
FRP-1 0 Fiberglass Reinforced Wall Liner System Installation Erection
FRP-2 1 Fiberglass Reinforced Wall Liner System Installation Erection
HM-4HR 4 STANDARD 4 HOUR FIRE RATED SYSTEM Erection
HM-FIRE 5 Standard 1 And 2 Hour Fire Rated Wall System Erection
HM-FIRE-1HR 4 Standard 1 Hour Fire Rated Wall System Erection
HM-FIRE-2HR 0 STANDARD 2 HOUR FIRE RATED WALL SYSTEM Erection
HM-WALL-1HR 1 1 HOUR FIRE WALL DETAILS Erection
HM-WALL-2HR 2 Standard 2 Hour Fire Rated Wall System Details Erection
LIL-LR-1 1 Lock-In Wall Liner System With Lock Rails Installation Erection
LIL-LR-2 3 Lock-In Wall Liner System With Lock Rails Installation Erection
LIL-LR-3 4 Lock-In Wall Liner System With Lock Rails Installation Erection
LIL-LR-6 0 Lock-In Wall Liner System Partition Installation Erection
LILP-LR-1 1 Lock-In Plus Wall Liner System With Lock Rails Erection
LILP-LR-2 3 Lock-In Plus Wall LinerSystem With Lock Rails Erection
LILP-LR-3 4 Lock-In Plus Wall Liner System With Lock Rails Erection
PSK-GABLE 0 PSK Gable Liner Insulation Details Erection
PSK-LINER-HORZ 2 PSK Horizontal Wall Liner Insulation Details Erection
PSK-LINER-VERT 2 PSK Vertical Wall Liner Insulation Details Erection
13122A48 1 A48 Acoustical Wall SpecSheet
13122A49 1 A49 Acoustical Wall SpecSheet
13122FWL 1 Formed Wall Liner SpecSheet
13122LIL 1 Lock-In Wall Liners SpecSheet
13122STUD 1 6" Studwall SpecSheet
13122WI 0 Wall Insulation SpecSheet