Specifications

Adjustable Wall Louvers

Adjustable louvers will be of self-framing design. The louver frame will be of nominal 14-gauge formed aluminum and the louver blades will be nominal 12-gauge extruded aluminum. Finish will be natural mill finish and will not require field painting. Blades will be pivoted on 1/2" diameter aluminum pivot pins through nylon flanged bearings and operated by means of a pull-bar operating handle. All louvers will be complete with an exterior mounted 18-14 aluminum mesh insect screen.
- Optional:
  • Removable Filters
  • Motor operator – Available in:
    • 12 or 24 volt DC
    • 110/220 volt AC

Fixed Louver

Fixed louvers will be aluminum, general purpose type of self-framing design with free area of 63 sq. inches. Finish will be an aluminum mill finish. All louvers will be complete with #8 mesh screens.

Gable Louvers

Gable louvers will be fixed blade type with blades set on a 45 degree slope. Blades and frames will be 14-guage extruded aluminum with natural mill finish. Louver will include 18-14 aluminum mesh insect screens.

Turbine Vent

Turbine vent will be wind-driven rotary type gravity roof ventilator, with 8" or 12" diameter throat, fabricated from galvanized steel, externally braced.

Circular Roof Ventilator

Stationary ventilator for 3" or 4" roof will be gravity type with standard 12" diameter throat, fabricated from aluminum, and will be furnished complete with bird screen, operable disc type damper with chain, and base.

Power Roof Exhauster

Aluminum power roof exhauster for 3" or 4" roof will have a 12" diameter throat, capable of 280 CFM air movement at 1/8" static pressure and will be equipped with U.L. listed adjustable thermostat. Power requirements of exhauster will be .86 amps at 115 volts. An intake louver of 115 square inches minimum free air area will be required for each exhauster.

Ridge Ventilator (Gable Buildings Only)

Ridge ventilator will be of gravity type with 4" throat and chain operated vertical lift dampers. Ventilators will be made of nominal 24-gauge steel, factory-painted white on all visible exterior galvanized surfaces. Top of the ventilator will have a bird screen cover.

Drawings

Drawing Name Rev Description Type
A-CV 0 Circular 12" Stationary Roof Ventilator Approval
A-EF-12 0 12" Wall Mounted Exhaust Fan Approval
A-EF-14 0 14" Wall Mounted Exhaust Fan Approval
A-LA-16 0 16" X 24" Adjustable Wall Louver Approval
A-LA-3224 0 32" X 24" Adjustable Wall Louver Approval
A-LA-3232 0 32" X 32" Adjustable Wall Louver Approval
A-LA-48 0 48" X 42" Adjustable Wall Louver Approval
A-LF 0 Fixed Blade Wall Louver Approval
A-LG-1610 0 16" X 10" Fixed Blade Gable Louver Approval
A-LG-3212 0 32" X 12" Fixed Blade Gable Louver Approval
A-LG-326 0 32" X 6" Fixed Blade Gable Louver Approval
A-LG-4812 0 48" X 12" Fixed Blade Gable Louver Approval
A-LM-115-16 0 16" X 24" Wall Louver W/ 115 Volt Motor Operator Approval
A-LM-115-3224 0 32" X 24" Wall Louver W/ 115 Volt Motor Operator Approval
A-LM-115-3232 0 32" X 32" Wall Louver W/ 115 Volt Motor Operator Approval
A-LM-115-48 0 48" X 42" Wall Louver W/ 115 Volt Motor Operator Approval
A-LM-230-16 0 16" X 24" Wall Louver W/ 230 Volt Motor Operator Approval
A-LM-230-3224 0 32" X 24" Wall Louver W/ 230 Volt Motor Operator Approval
A-LM-230-3232 0 32" X 32" Wall Louver W/ 230 Volt Motor Operator Approval
A-LM-230-48 0 48" X 42" Wall Louver W/ 230 Volt Motor Operator Approval
A-LS-12-16 0 16" X 24" Wall Louver With 12 Volt DC Solenoid Approval
A-LS-12-3224 0 32" X 24" Wall Louver With 12 Volt DC Solenoid Approval
A-LS-12-3232 0 32" X 32" Wall Louver With 12 Volt DC Solenoid Approval
A-LS-12-48 0 48" X 42" Wall Louver With 12 Volt DC Solenoid Approval
A-LS-24-16 0 16" X 24" Wall Louver With 24 Volt DC Solenoid Approval
A-LS-24-3224 0 32" X 24" Wall Louver With 24 Volt DC Solenoid Approval
A-LS-24-3232 0 32" X 32" Wall Louver With 24 Volt DC Solenoid Approval
A-LS-24-48 0 48" X 42" Wall Louver With 24 Volt DC Solenoid Approval
A-PV 0 12" Power Roof Ventilator Approval
A-RV-10 0 10'-0" Ridge Ventilator Approval
A-RV-4 0 4'-0" Ridge Ventilator Approval
A-TV 0 8" or 12" Turbine Roof Ventilator Approval
ASK-2 7 Standard Accessory Stiffening Column Installation Erection
FAN-12XP 5 12" Exhaust Fan Details For "AEP" Buildings Erection
FAN-12XP-1 9 12" Wall Mounted Exhaust Fan Installation Erection
FAN-14-1 9 14" Wall Mounted Exhaust Fan Installation Erection
FAN-HOOD-1 2 Weatherhood Details For "AEP" Buildings Erection
LVR-A 8 Adjustable Wall Louver Details Erection
LVR-AC-MO 1 Wall Louver With AC Motor Operator Installation Erection
LVR-AC-MO-FIL 1 Wall Louver With AC Motor Operator & Removable Filter Installation Erection
LVR-DC-MO 0 Wall Louver With DC Motor Operator Installation Erection
LVR-FIXED 2 Fixed Blade Wall Louver Details Erection
LVR-G 3 Fixed Blade Gable Louver Details Erection
RIDGEVENT-AL 4 Ridge Vent Installation For Type 'AL' Building Erection
VENT-12 1 12" Roof Vent Details Erection
WOK 13 Basic Wall Opening Kit Details Erection
WOK-FIL-1 5 Wall Opening Kit With Partial Filler Panels Erection
WOK-FIL-2 3 Wall Opening With Reinforced Fillers Erection
13122AL 0 Adjustable Wall Louvers SpecSheet
13122FL 1 Fixed Louvers SpecSheet
13122GL 0 Gable Louver SpecSheet
13122RVF 0 Ridge & Circular Vent SpecSheet
13122RVM 0 Turbine & Power Vent SpecSheet